A while back I was developing a workflow scheduler. However the run duration kept coming back negative. The runs kept finishing like 15 seconds before they started. Eventually I figured out why; the company had configured a policy to use their custom NTP server, but it was 16.7 seconds off. So my Windows laptop's time was in the future, but the WSL VM (which ran the program) used another NTP server and was correct. In the end I just added a bodge that made the program request the time from an external server on startup to calculate an offset.

you are viewing a single comment's thread
view the rest of the comments
[โ€“] HamsterRage@lemmy.ca 5 points 2 days ago (1 children)

Should a CI server even have access to the Internet and need antivirus software? Maven access I guess.

[โ€“] bss03@infosec.pub 5 points 2 days ago

It is good to have a build method that doesn't require network access; at one time that used to be required for Debian builds. However, for a variety of reasons, most CI servers do have access to the network, even if there's a firewall (or NAT) between them and the Internet.