this post was submitted on 08 Feb 2026
495 points (96.3% liked)

Technology

80916 readers
4091 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 2 years ago
MODERATORS
 

The authorities apparently got tired of asking and just went in themselves.

Canada-based Windscribe, a VPN provider, just said that one of its European servers has been allegedly seized by Dutch authorities without a warrant. According to the company’s post on X, law enforcement said that they will return it to the service provider after they “fully analyze it.” It’s unclear why law enforcement impounded just a single rack from Windscribe’s cabinet, but the VPN provider said that it only uses RAM disk servers, meaning anyone who would look through the installed SSDs would only find a stock Ubuntu install on it, so the servers shouldn't hold any trackable data.

you are viewing a single comment's thread
view the rest of the comments
[–] BozeKnoflook@lemmy.world 22 points 1 day ago (11 children)

Police have had, since the late 90s I think, the "Hotplug" which is a special battery pack / generators that provide a special power plug where you can gently loosen the existing plug, slide the generator's plug in place over it, then remove the computer from the main supply while keeping it powered on.

Power plug locks only buy you time or prevent casual mayhem; the police can work around those.

[–] Strawberry@sh.itjust.works 14 points 1 day ago* (last edited 1 day ago) (5 children)

I'm intrigued how that would work with some styles of plug that disconnect before coming out of the socket like the uk type-G plugs. Unless they're not touching the socket itself and connecting somewhere else? I have no idea, i'm not an electrician.

[–] Passerby6497@lemmy.world 26 points 1 day ago (1 children)

It doesn't matter for server class hardware, they generally have dual PSUs to ensure they stay up if one of the two lines fails. So unplug one side, plug in your backup/mobile supply, the disconnect everything else and then run away with the blade

[–] Strawberry@sh.itjust.works 4 points 1 day ago

oh yes that makes a lot of sense for server stuff. I imagine that may be quite useful for general use & maintenance too.

I'm too caught up thinking of consumer stuff.