this post was submitted on 03 Jun 2026
420 points (97.9% liked)

Technology

85136 readers
4277 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 3 years ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] squaresinger@lemmy.world 23 points 14 hours ago* (last edited 11 hours ago) (6 children)

The headline looks wrong, but it actually isn't.

The article specifies:

  • Total capacity: 2.1GWh
  • Peak output: 1.2GW
  • Ramp up time: a few milliseconds

That's what the "within milliseconds" in the title refers to.

Every power generator has a ramp up time. Think the time it takes to start the engine in a diesel generator, until it spins up and is able to output peak power.

Nuclear reactors can hare ramp-up times of hours, in some conditions even days.

This thing here can go from zero to peak output within almost no time, which makes it perfect to balance the sometimes erratic and unpredictable generation fluctuations of renewable energy production.

For comparison, coal or gas power generators usually have large flywheels that, once spinning, react almost instantly to power fluctuations in the network by converting their motion to electricity or the other way round. If these coal or gas generators aren't running, they can't be used to balance the fluctuations in the network, so battery solutions like the one in OP are required to actively manage the network stability.

[–] LovableSidekick@lemmy.world 3 points 8 hours ago* (last edited 8 hours ago)

Perfect power source for a Death Star! The planet goes from zero to smithereens in milliseconds!

[–] Vex_Detrause@lemmy.ca 4 points 9 hours ago (1 children)

That's like a huge capacitor on my hobby electronics brain.

[–] squaresinger@lemmy.world 2 points 6 hours ago

That's pretty much the job, except a billion times as large.

[–] Knock_Knock_Lemmy_In@lemmy.world 1 points 9 hours ago (2 children)

FYI. Hydro power has similar capacity and start up times

[–] squaresinger@lemmy.world 2 points 6 hours ago

Yeah, the downside of hydro though is that you need to have a fitting space to build it. You can't just excavate a random field somewhere and plonk a hydro dam right there.

In most places all easy spots for hydro are already taken.

[–] LovableSidekick@lemmy.world 4 points 8 hours ago (1 children)

Not quite - only the biggest hydro stations can generate a gigawatt or more, and their startup time is like 10 minutes.

[–] Knock_Knock_Lemmy_In@lemmy.world 3 points 7 hours ago (1 children)

This project is only 500 MW here

https://www.pv-magazine.de/2024/09/20/flexbase-plant-500-megawatt-redox-flow-speicher-in-der-schweiz/

And other places say 800 MW

Both of which are comparable to large hydro.

Modern pumped hydro has a ramp up in the 10s of seconds range.

Anyway. Same ballpark in terms of power.

[–] LovableSidekick@lemmy.world 1 points 7 hours ago

I must have got the 1.2GW from some comment.

[–] Gsus4@mander.xyz 3 points 13 hours ago (1 children)

Thanks, I edited the headline to make it clearer, but this community is overrun with confidently incorrect folks.

[–] LovableSidekick@lemmy.world 2 points 8 hours ago

...this community - oh, you mean social media! Yes, quite true.

[–] Kazumara@discuss.tchncs.de 1 points 12 hours ago (2 children)

Peak output needs to be 1.2 GW not GWh.

[–] squaresinger@lemmy.world 1 points 11 hours ago

Correct, the typo is mine, not from the article.

[–] Nighed@feddit.uk 1 points 12 hours ago

I thought that issue was considered solved by smart inverters now?