this post was submitted on 15 Nov 2026
606 points (98.2% liked)

Technology

89869 readers
3555 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 3 years ago
MODERATORS
top 50 comments
sorted by: hot top controversial new old
[–] Trainguyrom@reddthat.com 7 points 8 hours ago

My job puts me in frequent contact with the safety team at a chemical plant. There are sensors all over the plant and warehouse and if the tiniest bit above nominal levels of quite few different chemicals is detected in the air, an audible alarm sounds and lights flash, along with automated reporting to safety team members.

My job does not involve interacting with chemicals, and my duties on the production floor are basically just rebooting printers and plugging computers back in as needed, so my instructions are basically "if the alarm goes off, immediately return to the office and listen out for any further instructions"

The fact that the monitoring mechanism literally only reported overage by email is a terrible design and the organization deserves whatever regulatory and legal backlash they receive for that decision

[–] njordomir@lemmy.world 11 points 1 day ago

I've been to Phantasialand. It was a nice park.

I have to agree with the other commenters. I feel like this is a task for a loudly audible alarm system and maybe a flashing strobe in the operators office, not an email.

[–] some_kind_of_guy@lemmy.world 54 points 1 day ago (2 children)

Subject: Fire.

Dear Sir/Madam,

~~I am writing to inform you of a fire that has broken out on the premises of 123 Cavendon Road.~~

Fire! Fire! Help me!

123 Cavendon Road. Looking forward to hearing from you.

Yours truly,
Maurice Moss

[–] jj4211@lemmy.world 8 points 1 day ago

A fire? At a sea parks?!

[–] MajorasTerribleFate@lemmy.zip 7 points 1 day ago (1 children)

I know he tried calling 0118 999 881 999 119 725 3 first, but had he not ended up with another country on the line it would have been a much quicker response.

So long as he organized and put all the objects on fire together, he'll be fine. Also don't use fire extinguishers from Britain apparently.

[–] Wildmimic@anarchist.nexus 94 points 1 day ago* (last edited 1 day ago) (1 children)

The technical standards for Email would allow for 3 days of delivery failure before finally giving up. That's the amount of leeway email has (in theory - practically we assume that everything longer than 3 minutes means something has gone wrong). Sending alerts by email is fine for non-critical applications; if one of my docker containers crash, an email is fine because the amount of damage is nil.

Why wasn't there an actual fail-safe mechanism employed that measures the chlorine levels and shuts the whole thing down BEFORE it gets dangerous?

This is not a Microsoft problem. This is a negligence problem on Phantasialands side, using inappropiate tools for a system that can hurt people on failure, and should be followed up by lawsuits.

[–] Agent641@lemmy.world 14 points 1 day ago (1 children)

From: noreply@carbondioxidedetector.com.au

RE: Carbon Dioxide leak detected

Message: To whom it may concern, an elevated carbon dioxide level was measured in the walk-in fridge in the bar kitchen. Probably one of the keg lines is leaking pressurised gas. Gas PPM is classified as alert level 5 - Immediately harmful to life. Please evacuate staff from the area and ventilate the fridge thoroughly before attempting entry with ELSRD hood donned to shut down gas flow.

Folder: Spam

[–] panda_abyss@lemmy.ca 9 points 1 day ago

Yeah

“Why do all our alerts go to spam”

Oh, well everyone just ignores them, then Jeff who isn’t even on the IT team but was on the mailing list was getting them. So Jeff marked them as spam instead of asking to be removed from the mail list, and now our corporate email provider just black holes them.

[–] Axolotl_cpp@lemmy.dbzer0.com 66 points 1 day ago* (last edited 1 day ago) (28 children)

Yeaaah not MS fault here, no sane person would rely solely on email for something like this

load more comments (28 replies)
[–] beejjorgensen@lemmy.sdf.org 420 points 2 days ago (9 children)

No mails arrived due to the disruption [...]. So no one noticed that the maintenance safety system of the sauna landscape has long since sounded the alarm by mail. Because the automatic dosing system had pumped too much chlorine into the pool.

Kinda scary to rely solely on email for such alarms.

[–] Remember_the_tooth@lemmy.world 228 points 2 days ago (8 children)

Yeah, I hate Microsoft as much as the next person, but this is 100% on Phantasialand for trying to cut corners with excessive automation.

[–] 2ndDegreeOWO@lemmy.world 99 points 2 days ago (2 children)

It's not excessive automation -- it's a lack of redundancy for critical safety features.

Anything safety-critical should never have a single point of failure if you can help it. And there was definitely an opportunity here to have some kind of secondary backup alarm system.

[–] raspberriesareyummy@lemmy.world 34 points 2 days ago

Nothing safety critical should ever go through microslop

load more comments (1 replies)
[–] tal@lemmy.today 117 points 2 days ago* (last edited 2 days ago) (1 children)

I think that automation is fine, but when you start talking about life-critical systems, the bar on failure modes and reliability becomes a lot higher. Like, if you have a sensor for excessive chlorine levels, the default probably should be not to keep pumping more of the chemical in, but to have some "hard" upper level where no more chlorine goes in (and if the two systems aren't directly-integrated, to at least let the maintenance safety system power off the chlorine system), and for a secondary alarm to be triggered (like, start playing a loud audible alarm) if maintenance doesn't respond to the email notification and indicate that they've dismissed the alert within a given amount of time. That's disruptive and undesirable compared to just emailing maintenance, but as long as there aren't any failures, you shouldn't ever see it. But if you do have it come up, you don't want the failure mode to be chemical-keep-being-dumped-into-the-system-and-people-being-unaware-of-it.

You want fail-safe behavior.

Automation can increase safety by decreasing time until an issue is addressed, for example. Automation isn't intrinsically incompatible with safety. Aircraft computers today use TCAS to automatically instruct pilots what to do if they are about to collide (and in fact, today the automated system is explicitly given higher priority than human air traffic controllers


if the two give pilots conflicting directives, the human is the one to be disregarded). But you gotta make your automated procedures have high reliability and handle failure the way you want when the consequences of a failure are high (and that goes for non-automated procedures too).

[–] panda_abyss@lemmy.ca 7 points 1 day ago

It’s like those supermarket fridges.

When these things go off a literal alarm needs to be screaming that there’s an issue.

Yes, you can set up additional email alerts and logging. But the primary mechanism needs to be an in your face loud uncomfortable alarm, and safety cutoffs like you said.

[–] Schemen110676@lemmy.ml 15 points 1 day ago (1 children)

No.. with the wrong kind of automation.

Safety relevant systems do not belong on public infrastructure

load more comments (1 replies)
[–] assaultpotato@sh.itjust.works 59 points 2 days ago (2 children)

Excessive automation? That actually seems like a great thing to have automated... just not by email. Nothing stopping them from having a sub ghz radio that sets off a physical alarm somewhere. Improper automation I think would be more apt. A purely local automated alarm sounds great, but the internet shouldn't be involved imo, at least not on the critical path to remediation.

load more comments (2 replies)
load more comments (4 replies)
[–] lornosaj@lemmy.world 18 points 1 day ago

In proper SRE, there is a rule - mails are not alerts and must not be used as such.

[–] Fmstrat@lemmy.world 4 points 1 day ago

100%. This is not because of an outage, this is because whoever set this up is an idiot.

load more comments (6 replies)
[–] Kazel@lemmy.dbzer0.com 48 points 1 day ago

fuck microslop but that one is 100% on Phantasialand

[–] thespcicifcocean@lemmy.world 14 points 1 day ago

What the fuck?

[–] GreenKnight23@lemmy.world 13 points 1 day ago (1 children)

Germans gassing people

2026

did not expect that on my bingo card.

[–] tyrefyre@sh.itjust.works 3 points 1 day ago

Those who do not study history are doomed to repeat it.

[–] absGeekNZ@lemmy.nz 24 points 1 day ago

Industrial automaton engineer here, I've worked on a bunch of safety critical systems and audited systems after incidents.

Best practice in situations were you are sending a remote start command, is for the stop command to be local to the pump controller.

I audited a system where the main control system sheet a start command to the dosing shed (which stored the concentrated chemicals), unfortunately the stop command was over the same link that got interrupted. The start was received but the stop was never was. Radio is not a reliable link.

For chemical dosing, I'd expect at least two types of command signals, such as concentration and Max allowed time; you could also measure the weight loss of the concentrate as a third check. Loss of communications to the main controller isn't necessity an instant stop, but I would expect a prolonged loss to trigger a stop. As long as the local controller has stop control, dosing can usually continue.

[–] magnue@lemmy.world 160 points 2 days ago (3 children)

Can't put any blame on MS here. Using email for safety warnings with no redundancy is negligent.

load more comments (3 replies)
[–] VAK@lemmy.world 9 points 1 day ago (1 children)

Why the fuck would you open the pool without getting a mail saying it is safe?

[–] cy888@lemmy.world 10 points 1 day ago (2 children)

The email is that there is a dangerous condition, not that it is safe.

[–] VAK@lemmy.world 1 points 12 hours ago (1 children)

That's such a rookie mistake to make in safety design..

Yeah, standardly you'd have someone manually check chemicals daily, and the automated system would correct chemicals when not in use, but where I grew up it isn't so much of a pool being "opened" as it was just that it's open around 365 days a year and less people just use it in "winter."

But if its 81F/27C outside on Christmas day, people will be swimming on Christmas..

[–] JcbAzPx@lemmy.world 4 points 1 day ago

I'm thinking maybe that should be the other way around.

[–] bob_omb_battlefield@sh.itjust.works 95 points 2 days ago (1 children)

This is why I always use Yahoo mail for my critical life safety notifications.

load more comments (1 replies)
[–] Blackmist@feddit.uk 6 points 1 day ago
[–] razen@lemmy.world 14 points 1 day ago (1 children)

This isn't MS fault, what happened to Normal Alarming System

load more comments (1 replies)
[–] Reygle@lemmy.world 5 points 1 day ago

GTFO of the cloud, you idiot humans

load more comments
view more: next ›