this post was submitted on 05 Jan 2026
725 points (98.7% liked)

Technology

78543 readers
3141 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 2 years ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] bstix@feddit.dk 9 points 5 days ago (1 children)

I was surprised when I read about it too, but it's true, they quite literally just plug them right into the normal plugs.

It works because there's a certain tolerance on the German breakers that allow for power to reverse. The balcony panels take advantage of this. However this also limits the possible output to whatever the tolerance is, otherwise it would overload and shut off or worse.

[–] just_an_average_joe@lemmy.dbzer0.com 0 points 5 days ago* (last edited 5 days ago) (2 children)

How does that even work? Panel would generate DC current and outlet would need AC. Then even when you have AC, you need to match the frequency, if outlet AC has a peak in its wave and panel has a trough, would this not cause problems? Also, does germany has pure sine wave electricity? Or is it like 3 line and 1 neutral?

Edit: nvm, i guess it has a normal on-grid inverter system built in

[–] j_j@muenchen.social 6 points 5 days ago (1 children)

@just_an_average_joe
You are right that this setup needs a DC-AC inverter often sold together with the PV panel and the inverter is designed for this purpose. It sort of rides on the sine wave from the outlet. Yes, this only works on one phase while the building gets 3 phases, but practically it does not matter since the meter sums all three phases.

There was some debate over the technical standard and meter type, German bureaucracy and lobbying!
@bstix

[–] j_j@muenchen.social 5 points 5 days ago

We fought to make it legal and solar from the balcony just works. You plug the device into your regular 220V AC outlet.

Wikpedia has pictures https://en.wikipedia.org/wiki/Balcony/_solar/_power

In Germany you can buy those in home-improvement stores or online. Your local lidl or aldi might have one occassionally.

@bstix @just_an_average_joe

[–] bstix@feddit.dk 4 points 5 days ago

It's the same grid as most of Europe. AC 3 phases 50 hz 230/400 V.

Other places can do the same, but it's a legal issue rather than technical. It's difficult to tax.