this post was submitted on 17 Sep 2025
263 points (98.5% liked)

Technology

75258 readers
3690 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 2 years ago
MODERATORS
 

Neat breakdown with data + some code.

you are viewing a single comment's thread
view the rest of the comments
[โ€“] humanspiral@lemmy.ca 2 points 6 hours ago (1 children)

Yes. Hydronic flooring is cheap at construction time. Complicated if drilling into finished ceilings/floor with thicker under floor space making. But instead of 9kw of winter electricity you are forced to import, it is free fall surplus generation. 100w of pump circulation.

But you are saying, a resistive boiler made more sense than a heat pump, with the hydronic floor conversion. At first I thought you were just saying resistive heating electric floor. The latter, to me, would be the cheapest capital outlay conversion, and then a heat pump would beat a resistive boiler on operation costs if hydronic.

Did you investigate all of these alternatives?

[โ€“] acchariya@lemmy.world 2 points 6 hours ago* (last edited 6 hours ago)

Yeah I already had the hydronic floors and ran numbers on heating the floors off thermal solar panels, propane, heat pump, and the resistive boiler. The thermal panels made the least sense because they are useless eight months of the year.

The heat pump might have worked but when I really needed it my semi-outdoor closet would be in single digits and full of water supply pipes so the heat pump would be least efficient when I needed it most, and would not help keep the closet warm.

The resistive boiler meant I could add a bunch of panels to run it during the day and get the floors up to 85F, then run all electric appliances with no worries during the day the rest of the year with the extra capacity. So instead of being net positive generation from 10am to 4pm in summer, its now 8 am to 6pm with way more than I can use at peak.