this post was submitted on 14 Sep 2026
98 points (98.0% liked)

Ask Lemmy

41408 readers
1248 users here now

A Fediverse community for open-ended, thought provoking questions


Rules: (interactive)


1) Be nice and; have funDoxxing, trolling, sealioning, racism, toxicity and dog-whistling are not welcomed in AskLemmy. Remember what your mother said: if you can't say something nice, don't say anything at all. In addition, the site-wide Lemmy.world terms of service also apply here. Please familiarize yourself with them


2) All posts must end with a '?'This is sort of like Jeopardy. Please phrase all post titles in the form of a proper question ending with ?


3) No spamPlease do not flood the community with nonsense. Actual suspected spammers will be banned on site. No astroturfing.


4) NSFW is okay, within reasonJust remember to tag posts with either a content warning or a [NSFW] tag. Overtly sexual posts are not allowed, please direct them to either !asklemmyafterdark@lemmy.world or !asklemmynsfw@lemmynsfw.com. NSFW comments should be restricted to posts tagged [NSFW].


5) This is not a support community.
It is not a place for 'how do I?', type questions. If you have any questions regarding the site itself or would like to report a community, please direct them to Lemmy.world Support or email info@lemmy.world. For other questions check our partnered communities list, or use the search function.


6) No US Politics.
Please don't post about current US Politics. If you need to do this, try !politicaldiscussion@lemmy.world or !uspolitics@lemmy.world


7) No Hit-and-Run questions.
Please don't delete your post for no apparent reason. If you plan on deleting a question later, say so in the post, or if you feel that you have a good reason to remove it, message a mod beforehand. It's not fair to the ones who took their time to answer, and it's not in the spirit of the community.


8) No Bots.
Posts or comments from bots, LLM's, AIs, Neural Networks, Transformers, or Marvin the Paranoid Android are not welcome in AskLemmy. Real humans only please.


Reminder: The terms of service apply here too.

Partnered Communities:

Tech Support

No Stupid Questions

You Should Know

Reddit

Jokes

Ask Ouija


Logo design credit goes to: tubbadu


founded 3 years ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] octobob@lemmy.ml 1 points 10 hours ago* (last edited 10 hours ago)

I use a really ancient analog hi-pot tester at work, which is basically a high potential insulation stress test. The hi-pot formula under UL is operating voltage x 2.25 + 2000v. It will put up to 40kV through a circuit at milli or micro amps to see if there is any leakage in the conductors through open air. This goes for bare conductors like busbars as well as insulated ones like wire, measuring their terminations or cracks in the insulation. It tests phase to phase and phase to ground to see if the electricity will jump thru air or over an insulated material, which is where the words strike and creep come from which have their own formulas of what is acceptable and what isn't for manufacturing and installation. There's a little more room for creep obviously.

All that is to say, there's plenty of fancy new digital hi-pot testers. We rented one for a project that was going on a marine grade system. They'll run a test at whatever your parameters you type in and save it all to a flash drive. We worked for 8 hours to set up all of our testing jumpers and ran a test for 1 second on the control wiring for it to say PASS then we put it all back together.

The fancy one saves the leakage current values to the drive. Our analog one will only display it on an analog dial and we write it down. This is ok for testing AC (and this is where things start to get a little over my head), something about the RMS nature of AC causes more leakage current during the test, so generally we have a leakage value of let's say 1 milliamp. DC will generally only make microamps of current when we run the test. Try recording any kind of value when you look at the dial and it looks like it doesn't even move past zero haha.

We basically told the customer that we have a pass/fail tester and can't accurately produce any type of value for leakage on DC unless we rented or purchased another machine. But for 9 out of 10 times, it's fine that's all anyone cares about anyway. I've fucked up and left a plate somewhere it shouldn't have been and believe me you'll know when this thing fails lol. It sent 11kV thru a tiny circuit board, whoops