Lemmy Shitpost
Welcome to Lemmy Shitpost. Here you can shitpost to your hearts content.
Anything and everything goes. Memes, Jokes, Vents and Banter. Though we still have to comply with lemmy.world instance rules. So behave!
Rules:
1. Be Respectful
Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.
Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.
...
2. No Illegal Content
Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.
That means:
-No promoting violence/threats against any individuals
-No CSA content or Revenge Porn
-No sharing private/personal information (Doxxing)
...
3. No Spam
Posting the same post, no matter the intent is against the rules.
-If you have posted content, please refrain from re-posting said content within this community.
-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.
-No posting Scams/Advertisements/Phishing Links/IP Grabbers
-No Bots, Bots will be banned from the community.
...
4. No Porn/Explicit
Content
-Do not post explicit content. Lemmy.World is not the instance for NSFW content.
-Do not post Gore or Shock Content.
...
5. No Enciting Harassment,
Brigading, Doxxing or Witch Hunts
-Do not Brigade other Communities
-No calls to action against other communities/users within Lemmy or outside of Lemmy.
-No Witch Hunts against users/communities.
-No content that harasses members within or outside of the community.
...
6. NSFW should be behind NSFW tags.
-Content that is NSFW should be behind NSFW tags.
-Content that might be distressing should be kept behind NSFW tags.
...
If you see content that is a breach of the rules, please flag and report the comment and a moderator will take action where they can.
Also check out:
Partnered Communities:
1.Memes
10.LinuxMemes (Linux themed memes)
Reach out to
All communities included on the sidebar are to be made in compliance with the instance rules. Striker
view the rest of the comments
If I understand the nomenclature correctly, your "consumer unit" is our "load panel" or "breaker box". We use 15A or 20A breakers for our typical outlets.
If you used unfused plugs, your lower-rated cords could potentially reach fire temperatures without drawing enough current to trip the breaker in the consumer unit. Which is why you use fused plugs: to protect the lower-rated wiring from higher current.
The US uses a different approach. If we used power cords rated to 5A for a 5A appliance, and we plugged them into a 20A circuit, we could have the same problem: A 15A fault current through this cord wouldn't trip the breaker, but could start a fire. So we don't do that. Even on our lowest current, corded appliances, we use a cord that is rated to carry a 20A fault current capable of tripping the breaker.
(You will occasionally find cords rated for 7A. This is 7A duty current, and the limitation is because of the specific appliance socket, which has a fuse immediately inside the casing, and other restrictions. The 7A rating is not on the wire itself. On these cords, the wiring is still required to have a fault current rating of 20A)
Oh that's an angle I never thought of -- protection via thicker wires designed to trip but not to heat. Very clever!